The *RCL command forces an ABORt command before resetting any parameters. ABOR cancels
any trigger actions presently in progress and sets INIT:CONT to OFF.
At power turn-on, recall is commanded at the memory location prior to turn-off state.
Command Syntax: *RCL <NR1>
Parameters: 0 - 99
Example: *RCL 1
Query Syntax: None
Related Commands; *RST, *SAV
4.5.9 Reset
This command resets the power supply to factory default states as defined below.
OUTP[:STAT] OFF
CURR[:LEV][:IMM] 0
CURR[:LEV]:TRIG 0
VOLT[:LEV][:IMM] 0
VOLT[:LEV]:TRIG 0
PER 0
INIT:CONT OFF
VOLT:PROT[:LEV] 110% of MAX
CURR:PROT[:LEV] 110% of MAX
*RST also forces an ABORt command.
Command Syntax: *RST <>
Query Syntax: None
Related Commands: None
4.6 Error Messages
System error messages are obtained with the SYST:ERR? query. The error number is the value
placed in the error queue. SYST:ERR? returns the error number and error message combined in a
string. When system errors occur, the Standard Event Status Register (ESR), records the error
groups as defined in Table 4.9. Table 4.10 lists system errors that are associated with SCPI
syntax errors and with interface problems.
Table 4.9 STANDARD EVENT STATUS REGISTER ERROR BITS