Returned Parameters: 0 | 1
Related Commands: None
4.3.10.3 CONT:EXT
This command enables or disables the external inputs for start, stop, arm, and clear.
The query command, CONT:EXT?, returns the status of external control.
Command Syntax: [CONFigure]:CONTrol:EXTernal <bool>
Parameters: 0 | OFF | 1 | ON
Examples: CONF:CONT:EXT ON
CONT:EXT 0
Query Syntax: [CONFigure]:CONTrol:EXTernal?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.4 INTE
This command enables or disables the external interlock feature. Interlock, described in Section
3.6, is used for applications where the power supply needs to be disabled under external
conditions.
The query command, INTE? returns the status of external interlock.
Command Syntax: [CONFigure]:INTErlock <bool>
Parameters: 0 | OFF | 1 | ON
Examples: CONF:INTE ON
INTE 0
Query Syntax: [CONFigure]:INTErlock?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.5 CONF:SETPT