4.3.12.3 NET:SER? (Optional Ethernet only)
This command sets the serial number of the Ethernet module. The serial number is an integer
ranging from 1 to 16777215 and cannot be altered by the user.
Query Syntax: [SYSTem][:COMMunicate]:NETwork:SER?
Parameters: None
Examples: SYST:COMM:NET:SER?
NET:SER?
Returned Parameters: <integer>
Related Commands: none
4.3.12.4 NET:ADDR (Optional Ethernet only)
This command sets the static address of the Ethernet module of the power supply. The factory
default address setting is 192.168.1.100.
Command Syntax: [SYSTem][:COMMunicate]:NETwork:ADDRess <string>
Parameters: IP address is represented with 4 bytes each having a range of 0-255
separated by dots
Examples: SYSTem:COMM:NET:ADDR 192.168.10.2
NET:ADDR 192.168.10.2
Query Syntax: [SYSTem][:COMMunicate]:NETwork:ADDR?
Returned Parameters: <string>
Related Commands: NET:MAC, NET:GATE, NET:SUBN, NET:PORT, NET:HOST,
NET:DHCP
4.3.12.5 NET:GATE (Optional Ethernet only)
This command sets the Gateway IP address of the Ethernet module of the power supply. The
factory default Gateway IP setting is 192.168.1.1.
Command Syntax: [SYSTem][:COMMunicate]:NETwork:GATE <string>
Parameters: Gateway IP address is represented with 4 bytes each having a range of 0-
255 separated by dots