Strany 2 - Silencing an Alarm

6 XR20 IntroductionHow your System OperatesYour system has been programmed to operate in one of threemodes: Area Arming, All/Perimeter, or Home/Sleep/

Strany 3 - Table of Contents

XR20 Arming and Disarming 7Area System ArmingArea Assignment: Your security system has been programmed intoseparate areas. The number of areas and th

Strany 4 - Emergency Evacuation Plans

8 XR20 Arming and DisarmingArea System DisarmingDisarming: While the system is armed, you can only enter thepremises through an exit/entry delay door

Strany 5 - Introduction

XR20 Arming and Disarming 9All/Perimeter System ArmingArea Assignment: Your security system is divided into two separateareas. Motion detectors, insi

Strany 6 - The Security Command Keypad

10 XR20 Arming and DisarmingAll/Perimeter System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit d

Strany 7

XR20 Arming and Disarming 11Home/Away System ArmingArea Assignment: Your security system is divided into two or threeseparate areas. Motion detectors

Strany 8

12 XR20 Arming and DisarmingHome/Away System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay

Strany 9 - Exit Error

XR20 User Menu 13User MenuSecurity Command User MenuMany of the features of your system have been put into a User Menuyou can access from any Security

Strany 10 - How your System Operates

14 XR20 User MenuUser Check-inUser Code Level: Master or StandardFunction: This feature allows you to monitor the arrival of childrenfrom school or em

Strany 11 - Arming and Disarming 7

XR20 User Menu 15Sensor ResetUser Code Level: Master or StandardFunction: Resets smoke or glassbreak detectors. Also clears Fireand Supervisory zone

Strany 12 - Arming and Disarming

Copyright © 1999 - 2002 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable.This information is subj

Strany 13 - Arming and Disarming 9

16 XR20 User MenuBypass ZonesUser Code Level: Master or Standard.Function: Allows you to bypass a zone prior to arming the system.Bypassing is usually

Strany 14

XR20 User Menu 17Using the Zone Monitor Function1. Access the User Menu.2. Press the COMMAND key until ZONE MONITOR? displays.3. Press any one of the

Strany 15 - Arming and Disarming 11

18 XR20 User MenuUser CodesUser Code Level: Master only.Function: Allows you to add or delete a user from the system orchange their user code or aut

Strany 16

XR20 User Menu 196. The display changes to MASTER? NO YES. Select YES to makethis a Master user level with the authority to access all UserMenu fu

Strany 17 - User Menu 13

20 XR20 User MenuDeleting User codes1. Access the User Menu.2. Press the COMMAND key until USER CODES? displays.3. Press any one of the Select keys.

Strany 18 - User Menu

XR20 User Menu 214. The keypad then displays OP (open) 00:00 PM MON followedby CL (close) 00:00 PM MON and DELETE KEEP. Press theSelect key under

Strany 19 - User Menu 15

22 XR20 User MenuZone Activity Check Event DisplayThis displays the date and time the Zone Activity Check was enabledor disabled.16-Character Display

Strany 20

XR20 User Menu 23Zone Bypass Event DisplaysThis displays the bypassing of system zones.16-Character Display Description26 BYPS 12 1017 Zone 26 bypa

Strany 21 - User Menu 17

24 XR20 User MenuArming and Disarming Event DisplaysThis displays any arming or disarming of system areas.16-Character Display DescriptionARM 3 1

Strany 22

XR20 User Menu 25User Code Change Event DisplaysThis displays any addition, deletion, or change to a user code.16-Character Display Description12 AD

Strany 23 - User Menu 19

Security Command® User's GuideXR20 Command ProcessorTM PanelsTable of ContentsSection Page Section PageAbout Your Security System ...

Strany 24

26 XR20 User MenuSystem Monitor Event DisplaysThis displays any loss of the system's AC power or battery.16-Character Display DescriptionPOWER T

Strany 25 - User Menu 21

XR20 System Setup 27System SetupWe have provided this System Setup section to allow you to track thecurrent status of the programmable options on your

Strany 26

28 XR20 System SetupHOW TO FILL IN THISTABLEUser - The User Number of theperson authorized to use thesystem.Level - Master or Standardauthority.Temp C

Strany 27 - User Menu 23

XR20 System Setup 29HOW TO FILL IN THISTABLEUser - The User Number of theperson authorized to use thesystem.Level - Master or Standardauthority.Temp C

Strany 28

30 XR20 AppendixThe relay activates forfive seconds during whichyou must open the door.Once you open the door,you have 40 seconds toexit and close th

Strany 29 - User Menu 25

XR20 Appendix 31ARMING AND DISARMING AN ALL/PERIMETER SYSTEMPress Command. The keypad displays PERIM ALL (when arming) or DISARM?. Pressthe Select

Strany 30

32 XR20 AppendixFA113 User's GuideThese instructions guide you through the operation of the XR20Command Processor system using the FA113 Wireless

Strany 31 - System Setup

XR20 Appendix 33Pager Direct™ User's GuidePager Direct uses the reporting capability of your security system to dial your pager number and send r

Strany 32 - User Codes

34 XR20 AppendixAccount NumberWhenever the system sends a message to your pager, it will sendthe account number first to identify itself. You will se

Strany 33 - HOW TO FILL IN THIS

XR20 Appendix 35PhoneAccess™ User's GuideThis exciting feature allows you to call your XR20 system from any outside touch-tone phone to arm and d

Strany 34 - Appendix

iiEmergency Evacuation PlansThe National Fire Protection Association recommends that youestablish an emergency evacuation plan to safeguard lives in t

Strany 35 - ENTRY DELAY

36 XR20 Appendix1. Call the panel phone number. The panel answers and sounds oneshort tone.2. Enter your code within 8 seconds. One beep means the c

Strany 36

XR20 Appendix 37Common Keypad DisplaysListed below are several keypad messages you may see on the display. Follow the instructions in the Possible So

Strany 37 - Appendix 33

38 XR20 IndexIndex24-Hour Zone, 4895 Voice Module, 36ALARM display, 3All/Perimeter, 10Arming, 9Disarming, 10Instant Arming, 9Ambush Codes, 20Area, 8Ar

Strany 38 - Alphanumeric Pager Display

This page has been intentionally left blank

Strany 40 - 895 Voice Module

XR20 Introduction 1About Your Security SystemYour Security Command system has been designed with your safetyand comfort in mind. It uses the latest i

Strany 41 - Appendix 37

2 XR20 IntroductionData Entry keysThese keys allow you to enter your user code when arming ordisarming, and enter other information into the system.Ba

Strany 42

XR20 Introduction 3Special Security Command TonesYour keypad also contains a small speaker that allows it to alert youto events as they occur on your

Strany 43

4 XR20 IntroductionUnderstanding Security System TermsThroughout this guide, and in some displays on your keypad, you willsee certain words or phrases

Strany 44 - LT-0303 (5/02)

XR20 Introduction 5Central Station MonitoringYour system can also be programmed to automatically send alarm,trouble, and arming and disarming reports